This website uses cookies primarily for visitor analytics. Certain pages will ask you to fill in contact details to receive additional information. On these pages you have the option of having the site log your details for future visits. Indicating you want the site to remember your details will place a cookie on your device. To view our full cookie policy, please click here. You can also view it at any time by going to our Contact Us page.

VSDs: A quick guide to specification

Author : Jeremy Salisbury

05 May 2011

The benefits of variable speed drives (VSDs) in several manufacturing applications are proven – energy-saving capabilities for centrifugal and regenerative type loads, process improvements, production flexibility, and an increased life for mechanical drive train components owing to lower stresses, etc

But the specifier needs to be sure they're not under or over-specifying in terms of the exact type, size and capabilities of VSD for their requirement.

Before even looking at VSDs, however, the full motor specifications and its load requirements need to be fully understood to avoid sizing and selection errors which could result in poor system performance, nuisance drive trips and ultimately production downtime.

Constant torque or variable torque?: The motor is a source of torque, which is relative to both power and speed, and the required torque/speed curves differ according to the application. The good news is that when selecting a VSD, most applications are suited to either a variable or constant torque drive.

Variable torque loads, which include centrifugal fans and pumps, rarely require much more than 100% overload on start-up, although large fans with high inertias generally have long ramp times and so these drives tend to be rated for 110% overload for 60 seconds.

The variable torque drive should have an adjustable parabolic v/f output to match the fan’s torque speed curve requirements and thus maximise available energy savings. It should also have a PI(D) input (again some drives offer further energy saving in PID mode) and where required the option for pump cascade control.

Constant torque loads feature generally in materials handling applications, such as conveyors, where the load remains constant across the speed range. It's important to know the overload requirements, as constant torque drives are rated differently between brands in terms of available power.

Some typically list two or three options, for example ‘light duty’ of 100% or no overload, ‘standard duty’ at 120% and ‘heavy duty’ at 150% (based upon 60 seconds). If in doubt, go for a drive with ‘heavy duty’ overload which will give the best chance of keeping the motor running in potentially unforeseen and demanding conditions.

Staying in control: The motor control mode should be understood to ensure correct drive selection. In general, constant torque drives range from simple and cost-effective V/F drives - ideal for applications without wide speed ranges or rapid load changes - through to the high-performance Vector Control series which, even in SLVC, offer near ‘closed loop’ performance without needing an encoder.

Likewise, with regard to interfacing and controlling the inverter, consideration should be given to input/output requirements, for example, the number of digital I/O and functionality, analogue I/O, PI or PID control, PTC/KTY input and so on. Field bus requirements - likely to be an optional extra - should also be established.

Generally, basic V/F drives have limited I/O while SLVC drives are better equipped. The controls needed are often likely to determine drive selection, and again onboard I/O varies between brands – sometimes with surprising omissions.

The method of stopping the motor can also have an impact. For a controlled ‘ramp to stop’, the motor can usually be stopped in about the same time taken to ramp it up, without any special braking requirements. If rapid deceleration is required, DC injection braking may be needed, although the number of stops and the load’s inertia should be considered to ensure this will suffice.

Another option is dynamic braking where a brake chopper ‘dumps’ excess kinetic energy fed back from the load across a resistor. Without accurate inertia information, precise sizing of the resistor(s) is not achievable, but usually the standard manufacturer’s brake resistor will have a reasonably high peak load rating and suffice.

Regenerative braking is also becoming a more popular solution for AC drives. This is a ‘specialist’ drive solution offering obvious advantages over the traditional 4Q DC motor solution in terms of maintenance while still providing energy savings by returning the regenerative voltage back into the mains.

Harmonic and EMC requirements: The magnitude of these effects depends on factors including the characteristics of the line supply, point of common coupling, the type of inverter and power. And although the end user is responsible for the quality of their supply and the network they are connected to, often they will not know much about their supply system, fault levels and existing harmonics, meaning that without a power quality survey, specifying the right drive is often a matter of judgement.

In general, when specifying standard drives the best advice is to recommend an input choke, especially for 1AC drives 3kW or over and 3AC drives 37kW and over. In order to meet a specific EMC level a choke may also be mandatory.

The decision on whether an output choke is required will depend largely on the length of the motor cables (combined if more than one motor is being driven) and whether the cable is shielded or not. Finally, the end user will often be able to specify whether an RFI filter is required. This is generally a must for 1AC fed drives.

Once selected, correct installation and commissioning is vital – indeed, any VSD will only perform as well as it is commissioned. When AC drive inverters are operated, they have undesirable effects on the line supply. This is caused by the non-linearity of the device and the high control frequency of the output transistors.

* Jeremy Salisbury is head of Marketing, Brammer UK


Contact Details and Archive...

Print this page | E-mail this page

RELATED CONTENT...


Article image Introducing Unidrive HS30 and HS70 – drives designed for high speeds

Emerson has expanded its Control Techniques variable speed drive range with two new models designed specifically for applications which demand high speeds.Full Story...

Article image VACON extends its powers

The popular VACON 100 range of AC variable speed drives has been extended to include models rated up to 800 kW. Full Story...

Atlas Copco’s new GA 7-15 VSD+ compressor range provides 50% energy savings

Baking a better biscuit with variable-speed drives

Siemens Congleton celebrates 40 years

RELATED SPONSORED ARTICLES...


Article image Atlas Copco’s new GA 7-15 VSD+ compressor range provides 50% energy savings

Atlas Copco Compressors has launched the biggest innovation in small compressor technology in 20 years.Full Story...

Article image ABB technical guides offer independent advice

ABB has produced a range of technical guides that offer concise explanations of the major technologies and technical issues in motor and variable speed drive operationFull Story...

MOST VIEWED...


Article image Here are your 2017 Food Processing Award finalists...

The Food Processing Awards are designed to acknowledge and recognise companies for their excellence and innovation within the UK food and beverage engineering sector. The 2017 Awards ceremony will be held at the DoubleTree by Hilton Hotel, Coventry on the evening of the annual Appetite for Engineering event on 19th October (which is taking place at the Manufacturing Technology Centre in Coventry). Full Story...

Article image Conveyors as efficiency and productivity improvement tools

Conveyors are a critical link between processing operations. Despite this they are often not given due consideration when designing processing lines. Food Processing looks at a variety of applications which demonstrate the important role that conveyors can play in helping maximise efficiency and productivity. Full Story...

Consumers blame producers for food fraud

Don’t waste your process heat – reuse it

Manual boiler blowdown is responsible for boilerhouse overspending

http://www.appetite4eng.co.ukhttp://www.fponthenet.net/whitepapers.aspx