This website uses cookies primarily for visitor analytics. Certain pages will ask you to fill in contact details to receive additional information. On these pages you have the option of having the site log your details for future visits. Indicating you want the site to remember your details will place a cookie on your device. To view our full cookie policy, please click here. You can also view it at any time by going to our Contact Us page.

Atlas Copco: Energy recovery technology

22 February 2011

Anthony Cornes from Atlas Copco Compressors talks about the latest developments in energy recovery that make the energy efficiencies this technology offers easily accessible to an even wider range of manufacturing and process industries

Prudent energy managers would no doubt agree that in order to maximise energy efficiency, all areas of a compressed air system must be analysed to determine their potential to reduce energy consumption. But surprisingly, one area that is still overlooked, ignored, or rejected is the provision of an energy recovery system, perhaps because of the perceived complexity of installation and integration into an existing process.

Here, Food Processing talks to Anthony Cornes from Atlas Copco Compressors about the latest developments in energy recovery that make the energy efficiencies this technology offers easily accessible to an even wider range of manufacturing and process industries.

FP: So Anthony, tell us what’s been happening recently in relation to energy recovery technology?
Cornes: The biggest news is the launch of retrofit kits. When the Carbon Zero breakthrough in compressed air energy efficiency was announced in 2009, whereby 100% of electrical energy employed in compression can be recovered, the focus was on larger oil-free compressors up to 750kW with built-in energy recovery systems. Now, the introduction of retrofit energy recovery units for smaller, oil-lubricated rotary screw compressors means that a broad spectrum of manufacturing and process industries can now also save up to 94% of compression heat costs.

FP: What’s new about these units?
Cornes: Until recently, heat recovery methods applied mainly to larger, water-cooled compressors and were achieved via a heat exchanger in the oil circuit that provided hot water at comparatively low temperatures in the region of 50° - 60°C. But now, things have changed dramatically with the development of new oil/water heat exchangers that make it possible to retrofit stand-alone units to 11-90kW air-cooled machines, enabling between 72 to 94% of energy recovery to be achieved in the form of hot outlet water at temperatures of up to 90°C.

FP: How has that been achieved?
Cornes: By introducing the latest range of stand-alone, plug-and-play energy recovery units. The principal innovation is a completely new stainless steel oil/water heat exchanger that has been designed for simple installation, fast commissioning, reduced downtime and increased safety. All of the mechanical parts are pre mounted within the unit’s canopy, allowing easy access to the thermionic valve and the motor for servicing. The all-in-one-box configuration eliminates the possibility of incorrect connection of flexible hoses and parts. What’s more, no structural beam adaptation of the compressor is necessary to accommodate water inlet and outlet connections.

FP: How is the recovered heat utilised?
Cornes: Over 45% of industrial applications use hot water in their process operations. The highest degree of thermal efficiency is generally obtained when the compressor hot water outlet can be connected to a continuous heating demand, such as a heating boiler’s return circuit. The temperature level of the recovered energy determines the most appropriate applications.

As a general guide, these can be expressed in percentage terms related to temperature bands: The 51% ‘hot’ end of water temperatures from 60° - 90°C are ideal for boiler return heating and for heating buildings; the 29% band, 40° - 60°, is suited to hot water tap supply, while the remaining14%, water at 30° - 40°, can be utilised for pre-heating tap water, process water, supply air and maintaining background heating. There may well be other very specific roles within any particular process application.

FP: In a multiple installation, does it need a retrofitted energy recovery unit for each compressor?
Cornes: Not necessarily, it all depends on the number of installed compressors and their capacities. At present, the largest energy recovery unit is rated at 90kW therefore it could be linked to a single 90kW compressor or ‘daisy chained’ to a maximum of three 30kW machines or more units of lower capacity. The only limitation is that the total ratings of the linked compressors do not exceed those of the total energy recovery units.

FP: What are the cost/benefit ratios relative to energy recovery installations?
Cornes: If we look at the whole life cost components for an average compressor installation without any form of energy recovery, they can be divided as follows: Capital costs 21%, Service and maintenance 7%, Operating costs 72%. In comparison, an installation with an energy recovery system in place presents a much healthier picture for an organisation’s bottom line: Capital costs 23%, Service and maintenance 6%, and operating costs reduced down to 31% - so, at least , a significant 40% saving. In terms of return on investment, payback is generally achieved within one year of installation.

Whereas the amount of energy costs is linked to total operating time per year, the degree of utilisation and energy prices, capital investment costs such as these retrofit systems give a direct payback in the form of reduced operational and maintenance costs. It is also possible to achieve indirect process savings by reducing the maintenance costs of associated equipment and, in specific applications, the overall process efficiency can be boosted by up to 20%.


Contact Details and Archive...

Print this page | E-mail this page

RELATED CONTENT...


Article image Energy saving: a measure of success

Energy efficiency is moving up the agenda as fuel prices and environmental concerns continue to have an impact on the food and drink manufacturing sector. John Grenville suggests a solution to mitigate this. Full Story...

Article image Oil-free compressor breaks with tradition

Gardner Denver went back to the drawing board with the design for its new water cooled, oil-free compressor. The CompAir branded Ultima is said to offer improvements in energy efficiency of up to 12%, compared to a conventional two-stage machine. It also has a 37% smaller footprint. Full Story...

Atlas Copco’s latest GA 15-26 kW oil-injected screw compressors get efficiency boost

coolsuredoors launches new energy efficient refrigerated cabinet doors

Schneider Electric celebrates its 21st iso50001 accreditation

RELATED SPONSORED ARTICLES...


Article image Oil-free compressors for zero risk

Only oil-free air compressors deliver 100% oil-free air. We developed our oil-free compressors especially for applications demanding the highest levels of purity.Full Story...

Article image Oil-free compressors for zero risk

Only oil-free air compressors deliver 100% oil-free air. We developed our oil-free compressors especially for applications demanding the highest levels of purity.Full Story...

ABB Ltd wins EEF Green and Growth Award 2012

Unique new free online barcode problem-solver from Sick UK

Mechanical conveyors for the food industry from Spiroflow

MOST VIEWED...


Article image Spray and save on the glazing process

Food glazes are widely used in the bakery sector to improve the look and taste of baked products. Traditionally, this coating process has resulted in substantial waste. Technology advances mean that this is no longer the case. Full Story...

Article image Your flexible friend in the food factory

Suzanne Gill finds out where thermal imaging technology can help around the factory. Full Story...

A dry-ageing process improvement

Self diagnostics: an enabler for predictive maintenance

What role does refrigeration play in the supply chain?

ADDITIONAL INFORMATION...


New Whitepaper explains how to unlock energy savings and lower maintenance costs in steam boiler fe

http://www.appetite4eng.co.uk