This website uses cookies primarily for visitor analytics. Certain pages will ask you to fill in contact details to receive additional information. On these pages you have the option of having the site log your details for future visits. Indicating you want the site to remember your details will place a cookie on your device. To view our full cookie policy, please click here. You can also view it at any time by going to our Contact Us page.

Matching a UV system to an application

03 September 2017

Ultraviolet irradiation offers a good solution for liquid disinfection in the food and beverage industry. However, to get the best out of a UV system, it needs to be designed for the duty. Diane White offers advice on specifying the right solution for an application. 

To ensure that the design meets the application needs it is important to provide the UV supplier with enough information to allow it to not only select the right size of reactor but also to consider what other features may need to be built in to make the system complete. 

The first thing to define is the flow rate of the liquid to be treated. That sounds easy enough but it is necessary to provide not only the maximum, average and minimum flows but also the pattern of use. For example if the normal average flow is 5m3/hr for six hours per shift but the maximum is 10m3/hr for two hours it may be better to use two 5m3/hr units with one normally off line and just brought into service for the maximum flow. 

It is important to specify whether the flow continuous, and whether a standby stream is needed to cover for maintenance or breakdown? The minimum flow is important because some large UV reactors need a minimum flow to keep them cool. Equally important is whether the flow is intermittent. If the flow stops it may be necessary to switch the reactor off, but then, when it restarts it will need a warm-up time before it can guarantee to deliver the full germicidal dose and this may necessitate a run to waste or a recycle line.

Liquid characteristics
The next thing to consider are the liquid characteristics – most UV systems treat water but UV is also used to treat syrups, juices and similar solutions. The supplier will need to know the density, viscosity and temperature of the liquid including any maximum and minimum variations. For disinfection to occur the radiation has to pass through the liquid and the critical parameter here is the UV transmittance (UVT). This measures how much of the radiation power is lost by absorption or scattering of the rays in a 1cm path length through the liquid. It is usually measured in percentage so a liquid with UVT of 80% means that 20% of the UV lamp intensity will be lost in a 1cm path. Knowing this will allow the supplier to rate the reactor to compensate for this loss. Other useful characteristics are turbidity (a measure of colloidal particles that scatter light), colour and UV254 absorbance both of which indicate how much light is absorbed by the liquid. There are quite a few different units used for these measurements so make sure that you tell the supplier what they are.

Finally the UV dose (or fluence). A single pass through a standard UV system delivering a UV dose of 40 mJ/cm2 will typically achieve better than a 4 Log reduction (99.99%) of most bacteria and protozoans like Cryptosporidium. Some yeasts and moulds, however, require much higher doses so, if possible, let your supplier know what species are (or could be) present.

For UV to be effective it has to be delivered uniformly to all parts of the reactor so make sure that there is a UV monitor built in to the reactor to check that the required dose is being received. A single monitor can only check a single point in the reactor. Being certain that the applied dose is reaching all areas of the reactor depends on the reactor design. Reactor performance can be validated by type testing using independent third-party bioassay with live, surrogate microorganisms (typically bacteriophage T1 and MS2) against standardised test methods – the internationally accepted protocol is that of the US EPA so ask for a validation certificate to this effect.

Diane White is european sales manager at atg UV Technology.


Contact Details and Archive...

Print this page | E-mail this page

MOST VIEWED...


Article image Keeping cables and conduits and clean

Strict hygiene and cleanliness requirements apply to all equipment used in the food processing environment, including electrical components, cables and trunking. Food Processing finds out about a cleaning solution that utilises dry steam. Full Story...

Article image Appetite for Engineering event highlights the need to prepare for change

Suzanne Gill reports on this year’s Appetite for Engineering event, which took place at the Manufacturing Technology Centre (MTC) in Coventry on 19th October. 
Full Story...

Recognising innovation at the Food Processing Awards

Getting the best out of PLCs

Robots designed for the food industry

http://www.fponthenet.net/whitepapers.aspx?ShopItemID=1227https://www.siemens.com/uk/en/home/products/software/mindsphere/mindsphere-white-paper.html